Basit öğe kaydını göster

dc.contributor.authorDuz, Muhammed E.
dc.contributor.authorMenekse, Elif
dc.contributor.authorAvci, Burak Y.
dc.contributor.authorGumus, Alper
dc.date.accessioned2024-03-12T19:35:00Z
dc.date.available2024-03-12T19:35:00Z
dc.date.issued2023
dc.identifier.issn1433-6510
dc.identifier.urihttps://doi.org/10.7754/Clin.Lab.2022.220846
dc.identifier.urihttps://hdl.handle.net/20.500.12450/2792
dc.description.abstractBackground: Although analytical errors contain a small portion of laboratory errors, they are important in terms of intervention ability and practicality of follow-up by laboratory professionals. Also, from this point of view, the test results' quality, reliability, and accuracy are crucial to laboratories. Therefore, to determine analytical performance parameters for quality management in the analytical phase, clinical laboratories utilize total analytical error (TAE), bias, coefficient of variation (CV), and uncertainty of measurement (MU). Methods: Fifteen biochemistry parameters were compared with Beckman Coulter AU 5800 for 2017 - 2018 and Roche Cobas 8000 for 2019 - 2020 in terms of TAE and MU. The results were evaluated between devices and compared with the EuBIVAS, CLIA, RCPA, PRDEQA%, pUQEAS%, pU%, and TEa-TR datasets. Results: There were no significant differences between the devices for the mentioned periods. Device performances resulted in similar outcomes. During our four-year study, nearly all of our tests failed for EuBIVAS, RCPA, and pU%. On the contrary, almost all of our parameters gave valid results according to the CLIA, PRDEQA%, pUQEAS%, and TEa-TR ranges. Conclusions: It is crucial to distinguish between mistake and uncertainty. The discrepancy between the measured value and the 'actual value' is called error. Uncertainty is a measure of how confident you are in the measurement outcome. We endeavor to remedy any known inaccuracies wherever feasible by applying adjustments from calibration certifications. On the other hand, any inaccuracy whose value is unknown is a cause of doubt.en_US
dc.language.isoengen_US
dc.publisherClin Lab Publen_US
dc.relation.ispartofClinical Laboratoryen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjecttotal analytical error (TAE)en_US
dc.subjectallowable total error (ATE)en_US
dc.subjectmeasurement uncertainty (MU)en_US
dc.subjectaccuracyen_US
dc.subjectbiasen_US
dc.titleComparison of Two Clinical Chemistry Analyzers by Total Analytical Error and Measurement Uncertaintyen_US
dc.typearticleen_US
dc.departmentAmasya Üniversitesien_US
dc.authoridDUZ, Muhammed Emin/0000-0002-1837-6415
dc.identifier.volume69en_US
dc.identifier.issue1en_US
dc.identifier.startpage161en_US
dc.identifier.endpage171en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-85146406606en_US
dc.identifier.doi10.7754/Clin.Lab.2022.220846
dc.department-temp[Duz, Muhammed E.; Menekse, Elif; Avci, Burak Y.] Amasya Univ, Sabuncuoglu Serefeddin Training & Res Hosp, Med Biochem, Amasya, Turkiye; [Gumus, Alper] Basaksehir State Hosp, Med Biochem, Istanbul, Turkiyeen_US
dc.identifier.wosWOS:001096527000019en_US
dc.identifier.pmid36649508en_US
dc.authorwosidDUZ, Muhammed Emin/ABF-4918-2020


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster