Comparison of parallel or convergent proximal schanz screw placement of pertrochanteric fixator in intertrochanteric fracture model

xmlui.dri2xhtml.METS-1.0.item-rights

info:eu-repo/semantics/openAccess

Date

2017

Author

Gok, Arif
Inal, Sermet
Taspinar, Ferruh
Gulbandilar, Eyyup
Gok, Kadir

Metadata

Show full item record

Abstract

Intertrochanteric femoral fractures are serious traumas among elderly patients. In these patients, external fixator is a preferable method for the fixation of fractures. Therefore, this study was planned to compare the parallel and convergent proximal schanz screw placement of pertrochanteric fixator in the intertrochanteric femoral fractures with respect to biomechanical forces that stabilize the fracture line and to present their clinical importance. A commercial finite element based program, AnsysWorkbench was used to investigate the biomechanical parameters of the femoral intertrochanteric fractures and different placement of implants. The von Mises stress, von Mises strain and shear stress on the proximal and distal surface of the fracture line were lower in the convergent pertrochanteric fixator. Proximal schanz screws in convergent configuration pertrochanteric fixator had greater stress and strain values than proximal schanz screws in parallel configuration pertrochanteric fixator. The distance between the proximal schanz screws on the fracture line was measured as 12 mm in convergent configuration pertrochanteric fixator, and as 3.5 mm in parallel configuration pertrochanteric fixator. The angle between the proximal schanz screws in the convergent configuration was measured as 12.88 degrees. The effect of convergent and parallel configuration pertrochanteric fixators on axial loading demonstrated that convergent configuration pertrochanteric fixator was safer in this respect.

Source

MECHANICAL SCIENCES

Volume

8

Issue

2

URI

https://dx.doi.org/10.5194/ms-8-259-2017
https://hdl.handle.net/20.500.12450/1028

Collections

  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@Amasya

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess Type

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Instruction || Guide || Library || Amasya University || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
If you find any errors in content, please contact: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: