Basit öğe kaydını göster

dc.contributor.authorGok, Arif
dc.contributor.authorInal, Sermet
dc.contributor.authorTaspinar, Ferruh
dc.contributor.authorGulbandilar, Eyyup
dc.contributor.authorGok, Kadir
dc.date.accessioned2019-09-01T13:04:37Z
dc.date.available2019-09-01T13:04:37Z
dc.date.issued2017
dc.identifier.issn2191-9151
dc.identifier.issn2191-916X
dc.identifier.urihttps://dx.doi.org/10.5194/ms-8-259-2017
dc.identifier.urihttps://hdl.handle.net/20.500.12450/1028
dc.descriptionWOS: 000407714100001en_US
dc.description.abstractIntertrochanteric femoral fractures are serious traumas among elderly patients. In these patients, external fixator is a preferable method for the fixation of fractures. Therefore, this study was planned to compare the parallel and convergent proximal schanz screw placement of pertrochanteric fixator in the intertrochanteric femoral fractures with respect to biomechanical forces that stabilize the fracture line and to present their clinical importance. A commercial finite element based program, AnsysWorkbench was used to investigate the biomechanical parameters of the femoral intertrochanteric fractures and different placement of implants. The von Mises stress, von Mises strain and shear stress on the proximal and distal surface of the fracture line were lower in the convergent pertrochanteric fixator. Proximal schanz screws in convergent configuration pertrochanteric fixator had greater stress and strain values than proximal schanz screws in parallel configuration pertrochanteric fixator. The distance between the proximal schanz screws on the fracture line was measured as 12 mm in convergent configuration pertrochanteric fixator, and as 3.5 mm in parallel configuration pertrochanteric fixator. The angle between the proximal schanz screws in the convergent configuration was measured as 12.88 degrees. The effect of convergent and parallel configuration pertrochanteric fixators on axial loading demonstrated that convergent configuration pertrochanteric fixator was safer in this respect.en_US
dc.language.isoengen_US
dc.publisherCOPERNICUS GESELLSCHAFT MBHen_US
dc.relation.isversionof10.5194/ms-8-259-2017en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleComparison of parallel or convergent proximal schanz screw placement of pertrochanteric fixator in intertrochanteric fracture modelen_US
dc.typearticleen_US
dc.relation.journalMECHANICAL SCIENCESen_US
dc.authoridGulbandilar, Eyyup -- 0000-0001-5559-5281en_US
dc.identifier.volume8en_US
dc.identifier.issue2en_US
dc.identifier.startpage259en_US
dc.identifier.endpage266en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.department-temp[Gok, Arif] Amasya Univ, Technol Fac, Mech Engn, TR-05000 Amasya, Turkey -- [Inal, Sermet] Dumlupinar Univ, Sch Med, Dept Orthopaed & Traumatol, Campus Evliya Celebi, TR-43100 Kutahya, Turkey -- [Taspinar, Ferruh] Dumlupinar Univ, Sch Hlth Sci, Dept Physiotherapy & Rehabil, TR-43100 Kutahya, Turkey -- [Gulbandilar, Eyyup] Eskisehir Osmangazi Univ, Fac Engn & Architecture, Dept Comp Engn, Meselik Campus, TR-26480 Eskisehir, Turkey -- [Gok, Kadir] Manisa Celal Bayar Univ, Hasan Ferdi Turgutlu Teknol Fak, Mech & Mfg Engn, TR-45400 Manisa, Turkeyen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster