Basit öğe kaydını göster

dc.contributor.authorBayram, Halil
dc.contributor.authorYagmur, Haydar
dc.date.accessioned2025-03-28T07:23:22Z
dc.date.available2025-03-28T07:23:22Z
dc.date.issued2024
dc.identifier.issn2193-567X
dc.identifier.issn2191-4281
dc.identifier.urihttps://doi.org/10.1007/s13369-024-09430-7
dc.identifier.urihttps://hdl.handle.net/20.500.12450/6094
dc.description.abstractIn the present study, the hydrothermal performance of a gasketed plate heat exchanger was investigated experimentally and numerically. The numerical analyses were performed using the generated three-dimensional computational fluid dynamics models. Taguchi, ANOVA, and grey relation analysis statistical methods were also used to achieve the optimum parameter levels. The most and least effective parameters on the Nusselt number were mass flow rate (50.10%) and inlet temperature (5.58%), respectively. The most noticeable parameter of the Darcy friction factor was the chevron angle (91.21%), while the lowest was the inlet temperature, which had an effect of 0.49% (nearly negligible). In addition, the moderate design parameters on the Nusselt number and friction factor were the chevron angle (42.12%) and the mass flow rate (7.82%), respectively. The case of optimum levels of the parameters for the Nusselt number was not in the Taguchi L18 orthogonal array list. The Nusselt number was calculated as 86.276 and was even more significant than the highest value of 84.119 in the orthogonal array list results. In addition, the friction factor value was calculated as 0.521, considering the optimum parameter levels for only the friction factor. It was concluded that the mass flow rate and the chevron angle are the most effective parameters for maximum heat transfer and minimum pressure drop, respectively. The optimum parameter levels considering the multi-performance characteristics were obtained under the 30 degrees C inlet temperature, 0.25 kg/s mass flow rate, and 45 degrees chevron angle conditions. The Nusselt number and friction factor values were calculated as 73.876 and 0.802, respectively. The presented results can be used as a reference for similar studies, allowing the plate heat exchangers to be designed and used in battery thermal management and heating, ventilation, and air conditioning systems of electric vehicles.en_US
dc.description.sponsorshipAmasya University Scientific Research Projects (BAP) Coordination Department [FMB-BAP 20-0432]en_US
dc.description.sponsorshipThis study was supported by Amasya University Scientific Research Projects (BAP) Coordination Department under project number FMB-BAP 20-0432.en_US
dc.language.isoengen_US
dc.publisherSpringer Heidelbergen_US
dc.relation.ispartofArabian Journal For Science and Engineeringen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectChevron angleen_US
dc.subjectGasketed plate heat exchangeren_US
dc.subjectTaguchien_US
dc.subjectANOVAen_US
dc.subjectGRAen_US
dc.subjectCFDen_US
dc.titleThe Hydrothermal Performance Investigation of Gasketed Plate Heat Exchangers Using Taguchi, ANOVA, and GRA Methodsen_US
dc.typearticleen_US
dc.departmentAmasya Üniversitesien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-85201806940en_US
dc.identifier.doi10.1007/s13369-024-09430-7
dc.department-temp[Bayram, Halil] Amasya Univ, Engn Fac, Mech Engn Dept, TR-05100 Amasya, Turkiye; [Yagmur, Haydar] Amasya Univ, Grad Sch Nat & Appl Sci, Mech Engn Dept, TR-05100 Amasya, Turkiyeen_US
dc.identifier.wosWOS:001294985700001en_US
dc.snmzKA_WOS_20250328
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster