dc.description.abstractThree-pins head holder device has been safely used for many years in many neurosurgical procedures for providing 3-point rigid cranial fixation. Equal impingement of pins ensures firm skull positioning and fixation after carefully positioning of skull pins around the vessel free areas. The raw data of the three-dimensional computerized tomography angiography (3D-CTA) obtained from the patients with subarachnoid hemorrhage were transferred to computer and recorded in a software program. This software program created three-dimensional images of skull using previously transferred raw data with volume rendering technique. Safe areas for pins placement, in terms of vessel-free areas, were determined using three-dimensional volume rendering angiography of the skull. The study group consists of 53 (27 female and 26 male) patients. The mean age of the patients was estimated as 57.9±9.7 years. Branches, distribution and critical anastomosis of the superficial temporal artery were also determined. In the other way, the course of the posterior auricular and occipital artery ascending along the external surface of the mastoid bone was also detected in all cases. In the patients underwent surgery for intracranial aneurysm, using of three-dimensional volume rendering angiography may be used in the determination of vessel-free areas of the external surface of the scalp during the placement of three-metallic pins of head holder device. © 2016 OMU.en_US
dc.language.isoengen_US
dc.publisherOndokuz Mayis Universitesien_US
dc.relation.isversionof10.5835/jecm.omu.33.03.005en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMayfield-Kees head holder deviceen_US
dc.subjectPins placementen_US
dc.subjectThree-dimensional angiographyen_US
dc.titleUsing of three dimensional volume rendering angiography in the determination of vessel-free areas of the scalp in the patients underwent intracranial aneurysm surgery during the placement of three-pins metallic head fixation deviceen_US
dc.typearticleen_US
dc.relation.journalJournal of Experimental and Clinical Medicine (Turkey)en_US
dc.identifier.volume33en_US
dc.identifier.issue3en_US
dc.identifier.startpage151en_US
dc.identifier.endpage155en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.department-tempGokyar, A., Department of Neurosurgery, Faculty of Medicine, Amasya University, Amasya, Turkey -- Cokluk, C., Department of Neurosurgery, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey -- Marangoz, A., Department of Neurosurgery, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkeyen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster