Rotor Slot Distance Effects on Output Parameters inSingle Phase Induction Motors

Erişim

info:eu-repo/semantics/openAccess

Tarih

2018

Yazar

Merve Şen Kurt
Ahmet Fenercioğlu

Üst veri

Tüm öğe kaydını göster

Özet

I n this paper, single phase induction motor which has different rotor slot distances are analyzed with 2-D Finite Element Method (FEM). The analyses are carried out using ANSYS/Maxwell program which solves equations with FEM. The model has same stator and rotor slot geometry. The variable parameter is slot distance which is between outer diameter of rotor core and top border of slot. The single phase induction motor model has 2 poles, 96 W shaft power and run capacitor. It is connected to 220 V, 50 Hz AC network under the full load. Slot distance is varied from 0.2 to 1 mm in 0.1 mm steps. Magnetic model is solved for each distance. Electrical performance characteristics which are speed, efficiency, current, torque and power factor (PF) are determined. Magnetical flux density (B), flux lines and current density on bars are demostrated visually. Motor performance is improved as the slot distance decrease
 
I n this paper, single phase induction motor which has different rotor slot distances are analyzed with 2-D Finite Element Method (FEM). The analyses are carried out using ANSYS/Maxwell program which solves equations with FEM. The model has same stator and rotor slot geometry. The variable parameter is slot distance which is between outer diameter of rotor core and top border of slot. The single phase induction motor model has 2 poles, 96 W shaft power and run capacitor. It is connected to 220 V, 50 Hz AC network under the full load. Slot distance is varied from 0.2 to 1 mm in 0.1 mm steps. Magnetic model is solved for each distance. Electrical performance characteristics which are speed, efficiency, current, torque and power factor (PF) are determined. Magnetical flux density (B), flux lines and current density on bars are demostrated visually. Motor performance is improved as the slot distance decrease
 

Kaynak

Hittite Journal of Science and Engineering

Cilt

5

Sayı

1

Bağlantı

https://app.trdizin.gov.tr/publication/paper/detail/TWpjeU1qWTNOdz09
https://hdl.handle.net/20.500.12450/394

Koleksiyonlar

  • TR-Dizin İndeksli Yayınlar Koleksiyonu [1323]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Amasya

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim Şekli

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Yönerge || Rehber || Kütüphane || Amasya Üniversitesi || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: