• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Fluorimetric Reusable Polymeric Sensor for Hydrogen Sulfide Detection

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2023

Yazar

Ünaldı A.Ş.
Çubuk S.
Çiğil A.B.
Kahraman M.V.

Üst veri

Tüm öğe kaydını göster

Özet

In this study, with the help of reactive monomers, crosslinkers, and photoinitiator that detect H2S in various matrices, an H2S sensitive fluorescence sensor polymerizes under ultraviolet (UV) light was developed. To this goal, a polymeric membrane was prepared, and the characterization of the membrane was carried out with Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) methods. Afterward, appropriate conditions were identified, the excitation wavelength was determined as 370 nm, and the emission wavelength was determined as 425 nm. It was established that the fluorescence intensity of the prepared polymeric membrane decreased in the presence of H2S. A detailed analysis was executed to determine the sensor's most suitable pH value and time. It was found that the optimum pH was 8.0, and the optimal duration was 15 s. It has been calculated that the linear range of the developed method is 2.19 × 10–8– 6.25 × 10–7 M, and the detection limit (LOD) is 7.37 × 10–9 M. The effect of some possible interfering ions was investigated, and it determined that the sensor had excellent selectivity. In addition, the sensor used to determine H2S can be used at least 100 times. The recovery percentages were 102.1%–103.2%, and 104.6%, using tap water samples. In terms of providing reliable, fast results, high sensitivity, reusable, low cost, and ease of use, the developed fluorimetric sensor, compared to standard methods, has become more advantageous. © 2023, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Cilt

33

Sayı

4

Bağlantı

https://doi.org/10.1007/s10895-023-03181-8
https://hdl.handle.net/20.500.12450/2850

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [458]
  • Scopus İndeksli Yayınlar Koleksiyonu [1574]

İlgili Öğeler

Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.

  • Anomaly detection with low magnetic flux: A fluxgate sensor network application 

    Ege, Yavuz; Coramik, Mustafa; Kabadayi, Murat; Citak, Hakan; Kalender, Osman; Yuruklu, Emrah; Kurt, Unal; Nazlibilek, Sedat (ELSEVIER SCI LTD, 2016)
    Recent studies on remote detection methods were mostly for improving variables like sensing distance, sensitivity and power consumption. Especially using anisotropic magneto-resistive sensors with low power consumption and ...
  • DESIGN AND MANUFACTURE OF A NEW TWO AXES WELDING SEAM TRACKING SYSTEM USING LASER SENSOR FUZZY LOGIC CONTROL 

    Duzcukoglu, Hayrettin; Aydogdu, Omer; Ozturk, Ahmet; Akkus, Harun (YILDIZ TECHNICAL UNIV, 2018)
    In this study, a welding seam tracking system that is unique to the three axes (X-Y-Z) controlled application with laser sensor was put into practice. In the study, the monitoring of the planar axes (X-Y) of the torch was ...
  • Vertical CdTe:PVP/p-Si-Based Temperature Sensor by Using Aluminum Anode Schottky Contact 

    Cetinkaya, Hayriye Gokcen; Cicek, Osman; Altindal, Semsettin; Badali, Yosef; Demirezen, Selcuk (Ieee-Inst Electrical Electronics Engineers Inc, 2022)
    vertical Schottky barrier diode (SBD)-based temperature sensors with the drive modes are a signifi-cant issue with more advantageous than the on-chip sensor. The sensitivity (S) and the current conduction mechanisms (CCMs) ...



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Amasya

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim Şekli

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Yönerge || Rehber || Kütüphane || Amasya Üniversitesi || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: