• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effect of steel-FRP ratio and FRP wrapping layers on tensile properties of glass FRP-wrapped ribbed steel reinforcing bars

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2021

Yazar

Basaran, Bogachan

Üst veri

Tüm öğe kaydını göster

Özet

One of the many alternative methods developed to address the corrosion problem of steel reinforcements is the use of hybrid reinforcement composed of a fiber-reinforced polymer (FRP)-wrapped ribbed steel reinforcing bars. However, the number of layers and thickness of the FRP wraps on the ribbed steel core affect the mechanical properties of the glass FRP (GFRP)-steel hybrid reinforcement. In this study, in order to increase the ductility of the hybrid reinforcements, 27 types of hybrid bars were produced by wrapping E-glass fibers at an angle around the steel reinforcement using the filament winding method. The effects of steel reinforcement diameter (8, 10 and 12 mm), steel-FRP ratio and number of glass fiber layers (one, two and three layers) on the tensile properties of hybrid reinforcement were investigated. The experimental results on hybrid bars were compared to the respective values of the plain GFRP and carbon FRP (CFRP) reinforcing bars as well as the results on hybrid bars in the literature. In addition, a theoretical stress-strain model was proposed for the GFRP-wrapped steel reinforcing bar. The study showed that increasing the FRP ratio in the hybrid reinforcement increased the ductility of the reinforcement, although the yielding stress was reduced. The strain of glass-wrapped ribbed steel reinforcements under maximum stress varied between 4.14 and 6.22%. The energy absorption capacity of the GFRP-wrapped reinforcement was observed to be higher than that of the plain GFRP, CFRP and the other hybrid bars. In addition, the developed theoretical model was found to be compatible with the experimental results.

Cilt

54

Sayı

5

Bağlantı

https://doi.org/10.1617/s11527-021-01775-x
https://hdl.handle.net/20.500.12450/2522

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [1574]
  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Amasya

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim Şekli

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Yönerge || Rehber || Kütüphane || Amasya Üniversitesi || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: