• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comprehensive energy, exergy, and economic analysis of the scenario of supplementing pumped thermal energy storage (PTES) with a concentrated photovoltaic thermal system

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2022

Yazar

Kursun, Burak
Okten, Korhan

Üst veri

Tüm öğe kaydını göster

Özet

The pumped thermal energy storage (PTES), which is designed to store electricity more cheaply, is one of the issues that have been discussed in recent years. In the PTES system, electrical energy is stored as hot water employing a heat pump, and when needed, it is converted back into electrical energy by using a heat engine. As a result of supporting the PTES system with a heat source, the performance coefficient of the heat pump is increased, thereby increasing the round-trip efficiency of the system. These systems are called thermally integrated PTES (TI-PTES). The novelty in this study was the thermal integration method applied to the PTES system. In the thermal integration scenarios were given in the literature, solar collectors, geothermal sources, district heating, and industrial waste gas were used as heat sources. In the presented study, the part of photovoltaic modules in the system where the electricity to be stored was produced, was designed as a photovoltaic thermal system (CPV/T), and the hot water obtained from the CPV/T units was used to support the PTES system thermally. The proposed PTES system (TI(CPV/T)-PTES) was extensively evaluated in terms of thermodynamics and economics, and thermodynamic analyzes were carried out for different values of the design parameters of the CPV/T and PTES system. Depending on the change in parameter values, the electricity storage capacity of the system changed between 0.85 MW and 9.1 MW, and the round-trip efficiency changed between 48% and 81%. As a result of thermo-economic calculations, the lowest levelized cost of storage (LCOS) for the TI(CPV/T)-PTES system was obtained as 0.278 $kWh(-1). The results of the thermo-economic analysis revealed that lower LCOS values can be obtained in regions with higher solar radiation values. In addition, the TI(CPV/T)-PTES system was compared with other energy storage systems economically and a lower LCOS value was obtained for certain parameter values compared to Li-ion and VRF battery technologies.

Cilt

260

Bağlantı

https://doi.org/10.1016/j.enconman.2022.115592
https://hdl.handle.net/20.500.12450/2204

Koleksiyonlar

  • Scopus İndeksli Yayınlar Koleksiyonu [1574]
  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Amasya

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim Şekli

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Yönerge || Rehber || Kütüphane || Amasya Üniversitesi || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: