Basit öğe kaydını göster

dc.contributor.authorBayram, Halil
dc.date.accessioned2024-03-12T19:29:07Z
dc.date.available2024-03-12T19:29:07Z
dc.date.issued2022
dc.identifier.issn2214-157X
dc.identifier.urihttps://doi.org/10.1016/j.csite.2022.102406
dc.identifier.urihttps://hdl.handle.net/20.500.12450/2198
dc.description.abstractIn this study, the hydrothermal performance of the Double pipe heat exchangers(DPHEs) with a continuous and variable helical tape insert(HTI) conducted on the outer surface of the inner pipe was numerically investigated by using the generated three-dimensional(3D) computational fluid dynamics(CFD) models. The numerical analyzes were performed under variable pitch ratios (0.167 <=lambda <= 0.500), annulus side Prandtl number(Pr) (5.9 <= Pran <= 7.8) and Reynolds numbers(Re) (4200 <= Rean <= 16000) conditions. The numerical model was first validated for the conventional equal HTI DPHE model by comparison with experimental data obtained from the literature and empirical correlations. The validated model was then used to determine the effects of the variable HTI on the outer surface of the inner pipe. The relationship between the Nusselt number(Nu) and Darcy friction factor(f) was examined by using Grey Relation Analysis(GRA) method. The using of the denser HTIs on the tube side inlet region increases Nu about 9% compared with the con-ventional model. The f values of the models with variable HTI densities were calculated as higher than the Equal model under all Re conditions. The obtained results from the GRA method, con-ventional Equal model can be used for low Re, but the Inlet model can be preferred for 14000 and above Re conditions.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.ispartofCase Studies In Thermal Engineeringen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDouble pipe heat exchangeren_US
dc.subjectHelical tape inserten_US
dc.subjectVariable pitch ratioen_US
dc.subjectGRAen_US
dc.subjectCFDen_US
dc.titleAnalysis of numerical and grey relation method of the effect of helical tape insert density on the hydrothermal performanceen_US
dc.typearticleen_US
dc.departmentAmasya Üniversitesien_US
dc.identifier.volume39en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-85140082170en_US
dc.identifier.doi10.1016/j.csite.2022.102406
dc.department-temp[Bayram, Halil] Amasya Univ, Engn Fac, Mech Engn Dept, TR-05100 Amasya, Turkeyen_US
dc.identifier.wosWOS:000864030100002en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster