• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Mechanical behavior in terms of shear and bending performance of reinforced concrete beam using waste fire clay as replacement of aggregate

xmlui.dri2xhtml.METS-1.0.item-rights

info:eu-repo/semantics/openAccess

Date

2023

Author

Ozkilic, Yasin Onuralp
Basaran, Bogachan
Aksoylu, Ceyhun
Karalar, Memduh
Martins, Carlos Humberto

Metadata

Show full item record

Abstract

In this experimental and analytical study, waste fire clay (WFC) was consumed by the use of replacing fine aggregate (FA) in confident amounts. It is targeted to remove the current sustainable complications by confirming the consumption of WFC in reinforced concrete beams (RCBs) as raw materials. For this purpose, FAs were partially replaced with WFC in proportions of 0 %, 10 %, 20 %, and 30 %. Based on this motivation, a series of experimental studies were performed on 12 + 12 small-scale bending and shear RCBs of 100x150x1000mm, considering altered WFC and stirrup spacing. While the percentage of WFC in the RCBs was selected as 0 %, 10 %, 20 %, and 30 % by weight, correspondingly, the longitudinal reinforcement was taken into account as Phi 12, Phi 10, Phi 8. Besides, while the longitudinal tension and compression reinforcements of constant 2 Phi 12 and 2 Phi 6, the stirrup spacing was chosen as 160 mm, 200 mm, and 270 mm. As a result of the study, increasing the tensile reinforcement ratio has made the WFC less effective. Similarly, as stirrup spacing decreases, stirrup dominates the behavior, and as stirrup spacing increases, WFC determines the behavior. Finally, while the WFC content for bending RCBs increases the ability at the maximum level for the range of 20 % 30 %, it can be said that the optimum WFC content for shear RCBs is 20 %. The experimental results were obtained with the prediction of ACI-318 and the reason for the difference between the expected and actual values can be explained in detail.

Volume

18

URI

https://doi.org/10.1016/j.cscm.2023.e02104
https://hdl.handle.net/20.500.12450/2194

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [1574]
  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@Amasya

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess Type

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Instruction || Guide || Library || Amasya University || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
If you find any errors in content, please contact: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: