• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint

xmlui.dri2xhtml.METS-1.0.item-rights

info:eu-repo/semantics/closedAccess

Date

2014

Author

Mutlu, Ibrahim
Ugur, Levent
Celik, Talip
Buluc, Levent
Muezzinoglu, Umit Sefa
Kisioglu, Yasin

Metadata

Show full item record

Abstract

This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial cartilages for both acetabulum and femoral head. The dysplastic hip joint is modeled in three dimensional (3D) form using the computerized tomography (CT) images obtained in vivo of an adult female patient. The modeled hip joint components are manufactured as a non-natural dysplastic hip joint using different materials and manufacturing processes. The dysplastic hip joint produced is subjected to compression forces experimentally to measure the contact surface area and contact pressure distributions between the femoral head and acetabulum using the pressure sensitive Fuji film. Different types of specific fixtures and molds are designed and manufactured to produce the dysplastic hip joint components and perform the experimental studies. The measured results using a non-natural dysplastic hip joint are compared with relevant results reported in current literature considering the peak and mean contact pressure values. Therefore, the obtained results showed that the non-natural dysplastic hip models can be generated and replaced to determine the contact characteristics for an elusive cadaveric model. In conclusion, the artificial models might be useful to understand the contact pressure distributions and potential changes in surface pressure contours and their effects on the stress distributions.

Source

ACTA OF BIOENGINEERING AND BIOMECHANICS

Volume

16

Issue

2

URI

https://dx.doi.org/10.5277/abb140213
https://hdl.handle.net/20.500.12450/1455

Collections

  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@Amasya

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess Type

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Instruction || Guide || Library || Amasya University || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
If you find any errors in content, please contact: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: