dc.contributor.author | Gok, Kadir | |
dc.contributor.author | Inal, Sermet | |
dc.contributor.author | Gok, Arif | |
dc.contributor.author | Gulbandilar, Eyyup | |
dc.date.accessioned | 2019-09-01T13:04:42Z | |
dc.date.available | 2019-09-01T13:04:42Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 0957-4530 | |
dc.identifier.issn | 1573-4838 | |
dc.identifier.uri | https://dx.doi.org/10.1007/s10856-017-5890-y | |
dc.identifier.uri | https://hdl.handle.net/20.500.12450/1053 | |
dc.description | WOS: 000401003300018 | en_US |
dc.description | PubMed ID: 28397164 | en_US |
dc.description.abstract | In this study, biomechanical behaviors of three different screw materials (stainless steel, titanium and cobalt-chromium) have analyzed to fix with triangle fixation under axial loading in femoral neck fracture and which material is best has been investigated. Point cloud obtained after scanning the human femoral model with the three dimensional (3D) scanner and this point cloud has been converted to 3D femoral model by Geomagic Studio software. Femoral neck fracture was modeled by SolidWorks software for only triangle configuration and computer-aided numerical analyses of three different materials have been carried out by AnsysWorkbench finite element analysis (FEA) software. The loading, boundary conditions and material properties have prepared for FEA and Von-Misses stress values on upper and lower proximity of the femur and screws have been calculated. At the end of numerical analyses, the best advantageous screw material has calculated as titanium because it creates minimum stress at the upper and lower proximity of the fracture line. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | SPRINGER | en_US |
dc.relation.isversionof | 10.1007/s10856-017-5890-y | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | Comparison of effects of different screw materials in the triangle fixation of femoral neck fractures | en_US |
dc.type | article | en_US |
dc.relation.journal | JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE | en_US |
dc.authorid | Gulbandilar, Eyyup -- 0000-0001-5559-5281 | en_US |
dc.identifier.volume | 28 | en_US |
dc.identifier.issue | 5 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.department-temp | [Gok, Kadir] Manisa Celal Bayar Univ, Hasan Ferdi Turgutlu Technol Fac, Dept Mech & Mfg Engn, TR-45400 Manisa, Turkey -- [Inal, Sermet] Dumlupinar Univ, Sch Med, Dept Orthopaed Surg, Campus Evliya Celebi, TR-43100 Kutahya, Turkey -- [Gok, Arif] Amasya Univ, Technol Fac, Dept Mech Engn, TR-05000 Amasya, Turkey -- [Gulbandilar, Eyyup] Eskisehir Osmangazi Univ, Fac Engn & Architecture, Dept Comp Engn, Meselik Campus, TR-26480 Eskisehir, Turkey | en_US |