• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of the Effect of Diameters and Numbers of Cannulated Screws and Headless Compression Screws on the Reduction Stability in Transverse Patellar Fractures: A Finite Element Model Study

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2017

Yazar

Ugur, Levent
Karadeniz, Selami
Yildiz, Aytac

Üst veri

Tüm öğe kaydını göster

Özet

Background: Patella fractures constitute 1% of skeletal trauma. Transverse patella fractures are the most common types of patellar fractures. A fracture gap more than 2-3 mm or irregularities in cartilage require surgical treatment. There are various surgical options available, and one of these options is the screw fixation. This study aims to investigate the effect of the diameter and number of cannulated screws and headless compression screws on the reduction stability of transverse patellar fractures. Methods: In this study, the knee joint with normal anatomy and the knee joint with transverse patellar fracture were modeled using longitudinal lower extremity computerized tomography (CT) images taken in DICOM format. In the knee model with transverse patellar fracture, two circle divide 3.5 mm cannulated screws and one circle divide 4.5 mm cannulated screw, two circle divide 3.5 mm and one circle divide 4.5 mm headless compression screws were inserted respectively; and the maximum equivalent stresses (MES) occurred in the screws and the stability of the patella were examined in a total of 16 models at 30 degrees, 45 degrees and 60 degrees flexion angles and in the normal position (0 degrees) of the knee. The analysis was performed non-linearly and dynamically using ANSYS (version 17) and the same boundary conditions were applied in all models. Results: As a result of the analysis, the maximum stresses on the screws in the models with cannulated screws and headless compression screws were compared. When the maximum stresses in the screws were examined, it was observed that the maximum stress was lesser in the model with two circle divide 3.5 mm headless compression screws, and the maximum stress was found to increase in the single circle divide 4.5 screws. Sixteen different models were analyzed with the help of the Taguchi method and the most suitable model and parameters were determined according to the maximum equivalent von Mises stress value. Conclusions: The use of a single screw in the treatment of transverse patella fractures can lead to loss of reduction. If screw treatment is preferred, it was observed that the 2-screw application was more stable and the fixation with the headless compression screw was found to be more stable compared to the cannulated screw at various degrees of flexion.

Kaynak

JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING

Cilt

7

Sayı

10

Bağlantı

https://dx.doi.org/10.1166/jbt.2017.1651
https://hdl.handle.net/20.500.12450/998

Koleksiyonlar

  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Amasya

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim Şekli

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Yönerge || Rehber || Kütüphane || Amasya Üniversitesi || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: