THE 1-D ANALYSIS OF COOL DOWN SIMULATION OF VEHICLE HVAC SYSTEM

xmlui.dri2xhtml.METS-1.0.item-rights

info:eu-repo/semantics/openAccess

Date

2021

Author

Sevilgen, Gokhan
Bayram, Halil
Kilic, Muhsin

Metadata

Show full item record

Abstract

In this paper, a detailed combined 1-D model of HVAC systems of a vehicle were developed by using the LMS imagine LAB AMESIM software package. The numerical simulations were considered for soaking and cool down analysis under different environmental conditions. The thermal performance of different refrigerants as R-134a and R-1234yf were evaluated in terms of thermal performance and energy consumption. According to the soaking simulation results, the cabin air temperature values ranged from 49 degrees C to 57 degrees C in general. The maximum increase in cabin air temperature value was about 22 degrees C obtained for 1000 W/m(2) solar load. The total time until reaching the steady-state conditions for a target temperature value (23.5 degrees C) was different for all simulations. The total time was calculated as 910 seconds for 1000 W/m(2) solar load by using R-134a refrigerant loop. The results also showed that although the thermal performance of R-134a was slightly better, R-1234yf can be used due to its environmental properties with acceptable performance. The calculated COP values during cooldown analysis were ranged from 1.71 to 4.52 in general. The minimum value was obtained for the cases which had a maximum solar load and higher cabin interior temperature values. The calculated temperature data for soaking and cool down analysis were in good agreement with the reference data presented in this study. These numerical results are very important for reducing the thermal load of the vehicle cabin considering energy consumption of the HVAC system for different thermal conditions.

Volume

25

Issue

3

URI

https://doi.org/10.2298/TSCI191016099S
https://hdl.handle.net/20.500.12450/2582

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [1574]
  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@Amasya

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess Type

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Instruction || Guide || Library || Amasya University || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
If you find any errors in content, please contact: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: