• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace@Amasya
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Fatigue behaviors of different materials for schanz screws in femoral fracture model using finite element analysis

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2014

Yazar

Gok, Arif
Inal, Sermet
Taspinar, Ferruh
Gulbandilar, Eyyup
Gok, Kadir

Üst veri

Tüm öğe kaydını göster

Özet

In the daily life, human beings may be met with a number of undesired traumas. As a result, intertrochanteric fractures can occur in the skeletal system. Intertrochanteric femoral fractures are serious traumas that can lead to pneumonia, pulmonary embolism or death. Therefore, fixing as accuracy and stabilty of these fractures is necessary. The schanz screws with pertrochanteric fixator body are used for stabilizaiton of intertrochanteric fractures. Fatigue behaviors of the schanz screws must be longer than the duration of fracture consolidation. The aim of this study is to determine whether there are differences between fatigue behaviours of different materials for schanz screws when they are used for intertrochanteric femoral fracture fixation. Fatigue behaviors of schanz screws used for fixing of intertrochanteric fractures were analysed with ANSYS Workbench software using finite element analysis under dynamic loads for stainless steel and titanium. After the analysis, minimum fatigue life has been determined as approximately 21 months for the schanz screws having stainless steel while titanium has been determined as approximately 2 months. In addition, safety factor for schanz screws having stainless steel is calculated as 1.36 whereas safety factor for titanium is calculated as 1. Therefore, considering the consolidation of an intertrochanteric femoral fracture with a mean duration of three months, the titanium schanz screws shouldn't be used since their fatigue behavior is two months and safety factor is less than stainless steel.

Kaynak

OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS

Cilt

8

Sayı

5.Haz

Bağlantı

https://hdl.handle.net/20.500.12450/1425

Koleksiyonlar

  • WoS İndeksli Yayınlar Koleksiyonu [2182]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@Amasya

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim ŞekliBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreKategoriye GöreDile GöreErişim Şekli

Hesabım

GirişKayıt

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Yönerge || Rehber || Kütüphane || Amasya Üniversitesi || OAI-PMH ||

Amasya Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Amasya, Turkey
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz: openaccess@amasya.edu.tr

Creative Commons License
DSpace@Amasya by Amasya University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Amasya: