Search
Now showing items 1-10 of 28
CREATING THE MATHEMATICAL MODEL FOR THE SURFACE ROUGHNESS VALUES OCCURRING DURING THE TURNING OF THE AISI 1040 STEEL
(YILDIZ TECHNICAL UNIV, 2017)
In this research, AISI 1040 steel whose hardness is 46 HRc was processed in CNC lathe. Taguchi L-16 experiment design was created based on cutting speed, feed rate and depth of cut of which is consisted of four levels. As ...
Changes in the loadings on the shoulder girdle in the case of scapulothoracic fusion
(WILEY-BLACKWELL, 2016)
Background Scapulothoracic fusion (STF) may be an alternative and salvage procedure in the treatment of scapular winging. The biomechanical effects of this procedure on the shoulder girdle have not been previously considered. ...
Stress distribution comparisons of foot bones in patient with tibia vara: a finite element study
(WROCLAW UNIV TECHNOLOGY, 2013)
Blount's disease, or tibia vara, is the most common cause of pathologic genu varum in children and adolescents. Changes in the loading of knee structures such as tibial articular cartilage, menisci and subcondral bone are ...
Statistical analysis of surface roughness in turning process
(PAMUKKALE UNIV, 2017)
In this study, for the turning of AISI 1040 steel that has cylindrical shape and hardened up to 46 HRc, Taguchi L-16 experimental design was created according to the parameters of cutting speed, feed rate and cutting depth ...
The relationship between medial meniscal subluxation and stress distribution pattern of the knee joint: Finite element analysis
(ELSEVIER, 2016)
Background: Degenerative changes of the knee joint and clinical follow-up after meniscal subluxation are well documented. In the current study three-dimensional (3D) finite element analysis (FEA) of human lower limb was ...
The effect of proximal tibial corrective osteotomy on menisci, tibia and tarsal bones: a finite element model study of tibia vara
(WILEY-BLACKWELL, 2014)
BackgroundProximal tibial open wedge osteotomy (PTO) is a corrective operation used in the surgery of lower extremities and is applied to patients with varus deformities for sufficient correction. The aim of the study was ...
Evaluation of contact characteristics of a patient-specific artificial dysplastic hip joint
(WROCLAW UNIV TECHNOLOGY, 2014)
This study addresses the results of the experimental measurements for the contact surface areas and contact pressure distributions of a dysplastic hip joint. The hip joint consists of pelvis, proximal femur and artificial ...
Investigation of effect on energy consumption of surface roughness in X-axis and spindle servo motors in slot milling operation
(ELSEVIER SCI LTD, 2019)
The energy cost is a significant expense in the machining companies, and the reduction of energy consumption has a critical prescription in the industry. To increase energy efficiency, machine producers have contributed ...
Investigation of Fatigue Behaviour of Plate Applications in Clavicle Fractures by Finite Element Method According to the Plate Replacement Position
(GAZI UNIV, 2019)
Background: The clavicle is an anatomical structure which has an important role on the movements of the shoulder and arm. Clavicular fractures are a common problem in skeletal system injuries. The main purpose is to achieve ...
Hemodynamic effect of bypass geometry on intracranial aneurysm: A numerical investigation
(ELSEVIER IRELAND LTD, 2018)
Background and objective: Hemodynamic analyzes are used in the clinical investigation and treatment of cardiovascular diseases. In the present study, the effect of bypass geometry on intracranial aneurysm hemodynamics was ...